4
Sidaa manual calibration setting
0: Off
1: On
1: manually calibrates for communication with a line,
whose current change occurs such as an optical fiber line.
5-7 Not used Do not change the settings.
IP Fax Switches
IP Fax Switch 00 [SP No. 1-111-001]
No. FUNCTION COMMENTS
0 Not used Do not change this setting.
1
IP Fax Transport
0: TCP, 1: UDP
Selects TCP or UDP protocol for IP-Fax
2
IP Fax single port selection
0: OFF, 1: ON (enable)
Selects single data port.
3
IP Fax double ports (single data port)
selection
0: OFF, 1: ON (enable)
Selects whether IP-Fax uses a double port.
4
IP Fax Gatekeeper
0: OFF, 1: ON (enable)
Enables/disables the communication via the
gatekeeper for IP-Fax.
5
IP Fax T30 bit signal reverse
0: LSB first, 1: MSB first
Reverses the T30 bit signal.
6
IP Fax max bit rate setting
0: Not affected, 1: Affected
When "0" is selected, the max bit rate does not
affect the value of the DIS/DCS.
When "1" is selected, the max bit rate affects the
value of the DIS/DCS.
5. Appendix: Fax Service Program