Adjusting Magnification
1. Place the test chart on the exposure glass. Make sure the test chart is aligned with the rear and left
scales on the exposure glass.
2.
Make a copy.
3. Compare the copy with the original.
4. Adjust the main-scan and sub-scan magnifications. The original image [A] is magnified in the main-
scan direction [B] or in the sub-scan direction [C] when you specify a larger value.
• The diagrams show the paper on the copy tray. Note that the paper is output with the face down.
SP Specification
SP2-102-001 (Main scan Mag.) 0 ± 0.5%
SP4-008-001 (Sub Scan Mag.) 0 ± 1.0%
DF Image Adjustment
• Perform the adjustment procedure in this section only when the ARDF is installed on the copier.
4. Replacement and Adjustment
138