No.
Definition
Symptom Possible Cause
623 B
Second bank communication error
Abnormal code is send from the bank
unit.
Bad connection between the first
bank and the second bank
Defective the bank control board
NOT all connectors are in place
669 B
EEPROM communication error
Cannot return to be normal condition
after retrying three times when the error
on EEPROM communication occurs.
Defective the EEPROM
Noise
687 B
Cannot receive RAPI-PER
Command (Ready for image transfer) in
120 seconds after RARI-PES (Request for
image transfer) occurs.
Defective the controller board
Noise
790 B
Over the number of the banks installed error
Receiving a code other than the
following cord:
For Model S-C5: 01H 02H
More than 3 of the banks are
installed. (Specific limitation for
Model S-C5 is 2 at maximum)
901 B
Mechanical total counter error
The condition of the mechanical counter
on the electric hard is disconnection on
activating the counter when SP mode
“Anti-tampering system” is ON.
Defective harness between
mechanical counter and BICU.
Defective BICU
Defective mechanical total counter
Loose connection of harness
between mechanical counter and
BICU.
Mechanical counter has been pulled
out while accounting operation.
6. Troubleshooting