EasyManua.ls Logo

Ricoh D127 - Page 191

Ricoh D127
474 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
994-00 D
Over-limit OP panel administrative record error
The record, which composes the
display items and which is controlled
by the service layer, is over the certain
limit.
In using the operation panel, if
operating reaches deep layer with
multiple applications active, the
record may go over the limitation.
997 C
Application function selection error
The application selected by a key
press on the operation panel does not
start or ends abnormally.
Software for that application is
defective
An option required by the
application (RAM, DIMM, board) is
not installed.
Too complicated nest of the fax
group address
1. As for the fax operation problem,
simplify the nest of the fax group
address.
998 B
Application start error
After switching the machine on, the
application does not start within 60 s.
(No applications start or end
normally.)
Software for that application is
defective
An option required by the
application (RAM, DIMM, board) is
not installed.
1. Check the setting of SP5875-001. If
the setting is set to "1 (OFF)", change
it to "0 (OFF)".
SC Tables