1124 23 High: 3rd CPM Down Time.: A6 [0 to 999 / 0 / 1 sec/step]
1124 24
Judging Interval [1 to 999 / 10 / 1 sec/step]
For CPM down (Low temp.)
1124 25
Start Timing [1 to 999 / 10 / 1 sec/step]
After motor driving start, CPM down judge starts in SP’s value sec later. (Low temp.)
1152 Fusing Nip Band Check By-pass
1152 1
Check By-pass
Execution type SP
1152 2
Pre-idling Time [0 to 999 / 300 /1 sec/step]
Sets the duration of idling before the check takes place.
1152 3
Stop Time [0 to 100 / 20 / 1 sec/step]
Sets the duration of the check.
1159* Fusing Jam Detection
1159 1
SC Display [0 = No / 1 = Yes]
Enables or disables consecutive jam detection at the fusing unit. If this SP is set to "1"
(default: 0), consecutive fusing jam alarm occurs (SC559) when the machine detects
three consecutive paper jams at the fusing unit.
1902 Frequency
1902 1
Displays the fusing lamp power control frequency (as detected by the zero cross signal
generator).
1907 Paper Pre Feed Timing
1907 20 F2 Tray
[-10 to 10 / 0 / 1 mm/step]
The
larger value set, the larger area of the paper
is pre-fed for each tray.
1907 21 F3 Tray
1907 22 F2 Tray
1907 23 F3 Tray
3. Appendix: SP Mode Tables