2933* ID Sensor Control Correction [0.5 to 3 / 1 / 0.1 /step]
2933 1 For Adjustment of ID sensor correction value. DO NOT use this SP in usual operations.
2934* ID Sensor PMW Setting
2934 1 Dilay [0 to 1023 / 200 / 1 /step]
2934 2
Upper Limit Correction [0 to 1023 / 100 / 1 /step]
Sets PMW upper limit.
2935* ID Sensor Initialization
2935 1
Use this SP after ID Sensor replacement. This Operates PWM value clearing, Vsg re-
adjustment, and PWM re-adjustment.
2936* ID Sensor Detection Interval Counter
2936 1
[0 to 999 / 0 / 1 page/step]
The counter applying to “SP2-995-002”.
2992*
Copies After TD Sensor Error
“SP2992-002” is for “SP2992-001”. SC will occur after copying the number of sheets
chosen at “SP2992-001”.
2992 1 0= 100pages 1= 200pages -
2992 2 Counter [0 to 255 / 0 / 1 /step]
2995* ID Sensor Detection Interval
2995 1
Warming-up [0 to 999 / 480 / 1 min/step]
After energy saving mode activates, ID sensor warming-up will take place in this SP’s
value min later.
2995 2
Number of Pages [0 to 999 / 100 / 1 sheet/step]
Sets the number of pages as the trigger of “SP2-995-003” setting action. (Counter:
“SP2936-001”)