006 Distance 45k part
[0 to 255 / 0 / 1 /step]
Displays the PM distance Counter (45k) usage rate.
007 Distance 90k part
[0 to 255 / 0 / 1 /step]
Displays the PM distance Counter (90k) usage rate.
7804 PM Count Reset
001
Paper
Resets the PM counter (SP7-803-001). When the program ends normally, the message
"Completed" is displayed.
002 45k part PM counter (45k) clear
003 90k part PM counter (90k) clear
7807 SC/Jam Counter Reset
001
Resets the SC, paper, original, and total jam counters. When the program ends
normally, the message "Completed" is displayed.
SP7-807-1 does not clear the latest 10 JAM and SC logs.
7826
MF Error Counter
Displays the number of counts requested of the card/key counter.
001 Error Counter
A request for the count total failed at power on. This error
will occur if the device is installed but disconnected.
002 Error Staple
The request for a staple count failed at power on. This error
will occur if the device is installed but disconnected.
7827
MF Error Counter Clear
Press Execute to reset to 0 the values of SP7826.
7832* Self-Diagnose Result Display
001
Displays the SC codes and the number of their occurrences. Each number is in the range
of 0 to 9999.
3. Appendix: SP Mode Tables
110