Communication Switch 13 – Not used (do not change the settings.)
Communication Switch 14 [SP No. 1-104-021]
No FUNCTION COMMENTS
0
Inch-to-mm conversion during
transmission
0: Disabled 1: Enabled
0: In immediate transmission, data scanned in inch format
are transmitted without conversion.
In memory transmission, data stored in the SAF memory in
mm format are transmitted without conversion.
Note: When storing the scanned data into SAF memory,
the fax unit always converts the data into mm format.
1: The machine converts the scanned data or stored data
in the SAF memory to the format which was specified in
the set-up protocol (DIS/NSF) before transmission.
1-5 Not used Do not change the factory settings.
6-7
Available unit of resolution in
which fax messages are received
Bit 7: 0, Bit 6: 0 = mm
Bit 7: 0, Bit 6: 1 = inch
Bit 7: 1, Bit 6: 0 = mm and inch
(default)
Bit 7: 1, Bit 6: 1 = Not used
For the best performance, do not change the factory
settings.
The setting determined by these bits is informed to the
transmitting terminal in the pre-message protocol
exchange (in the DIS/NSF frames).
Communication Switch 15 – Not used (do not change the settings)
Communication Switch 16 – Not used (do not change the settings)
Communication Switch 17 [SP No. 1-104-024]
No FUNCTION COMMENTS
0
SEP (Selective polling) reception
Enabled/Disabled switch
0: Disabled / 1: Enabled
“Enabled” means SEP (Selective polling) is acceptable on
reception.