Loading...
2.17.13 Timing chart
Inversion Mode
Finisher ON
(Form Copier)
Exit (From Copier)
Inverter Entrance
Sensor
Inverter 2nd
Sensor
Inverter 3rd
Sensor
Inverter
Transport
Stopper Drive
Motor
Inverter Junction
Gate Solenoid
Jam Detection
1.1 sec. (Timer)
594 ms
(362 ms)
(332 ms)
(209 ms)
(471ms)
270 ms
40 ms
120 ms
40 ms
Entrance SN ON
2 sec. (Timer)
Entrance SN OFF
745 ms
2nd SN ON
540 ms
3rd SN
3rd SN OFF
96 pulses
Motor
High
Low
Up
315 ms
2nd SN OFF
705 ms
ON: ON Check
OFF: OFF Check
OFF
OFF
Down
100 ms
124.7 ms
Entrance
SN OFF
3rd SN
ON
*1
*2
*3
Finisher
1 July 1994