2.1.9 Adjusting the leading edge registration
Standard value: 0 ±2 mm in the platen
cover mode.
1. Set paper in the paper tray.
CAUTION
Be sure to set the paper side guides of the paper
tray securely.
2. Set the test chart on the exposure glass correctly.
3. Make a copy and measure the difference between the leading edge registration of the origi-
nal and the copy.
4. If the value does not match the standard, access service tool [5-02] and press the Registra-
tion key.
5. Change the value on the screen.
6. Make more than 10 continuous copies to check the variation.
7. Be sure that all copies are within the standard value. If problems still occur, repeat step 3 to
6.