SERVICE CALL CONDITIONS
G065 4-8 SM
SC Level Symptom Possible Cause
Fusing temperature warm-up error542 A
Fusing temperature does not
reach fusing standby temperature
of 45
°
C (113
°
F) within 14 s at
main power on or closing the front
cover.
20 seconds after reaching 50
°
C
the fusing roller does not reach
warm-up temperature.
Fusing lamp defective
Poor fusing unit connector
Thermistor warped or broken
Thermostat has tripped
BICU defective
Power supply board defective
Fusing overheat error (software
detection)
543 A
Fusing temperature of over 230
°
C
(446
°
F) is detected for 5 s by the
fusing thermistors at center or either
end of the fusing roller.
Power supply unit defective
I/O board (IOB) defective
BICU defective
Fusing thermistor defective
Fusing overheat error (hardware
circuit detection)
544 A
Dual-monitor circuitry of the BICU
detects an extremely high
temperature of 240
°
C (464
°
F) and
trips the relay circuit off.
Power supply unit defective
I/O board (IOB) defective
BICU defective
Fusing thermistor defective
Fusing lamp remains on545 A
After reaching warm-up temperature
with main motor on, the end fusing
lamp remains on at full power for 15
s, or the center fusing lamp remains
on at full power for 10s
Thermistor out of position.
Fusing ready temperature unstable546 A
After reaching warm-up temperature,
temperature fluctuations of 50
°
C
(122
°
F) within 1 s occur 2 times or
more.
Thermistor connection loose
Fusing unit connector loose
Zero cross signal malfunction547 B
The applied power supply ac
frequency detection is over 66 Hz or
below 45 Hz, and the zero cross
signals are not detected within 500
ms after the main power on.
Power supply board defective
Noise on the ac power line
Fusing unit installation error548 A
The machine cannot detect the
fusing unit when the front cover and
right cover are closed.
Fusing unit is not installed, or is
installed incorrectly
Fusing unit connection loose
C
OMMUNICATION AND
C
ONTROL
Communication timeout error
between BICU and finisher or
mailbox
620 C
The BICU does not receive a
response after 3 attempts within 100
ms to send data to the finisher or
mailbox.
Serial line connecting BICU and
finisher unstable
External noise
BICU board and finisher main
board connection defective or
loose
Finisher main board defective
BICU board defective