SERVICE CALL CONDITIONS
SM 4-9 G065
Trouble-
shooting
SC Level Symptom Possible Cause
Communication timeout error
between BICU and finisher or
mailbox
621 C
A break (low) signal is received from
the finisher or the mailbox.
Serial line connecting BICU and
finisher unstable
External noise
Communication timeout error
between BICU and paper tray unit
623 C
The BICU does not receive a
response after 3 attempts within 100
ms to send data to the paper tray
unit.
Serial line connecting BICU and
paper tray unit unstable
External noise
BICU board and paper tray main
board connection defective or
loose
Paper tray main board defective
BICU board defective
Communication break error between
BICU and paper tray unit
624 C
The BICU cannot communicate with
the paper tray unit because it has
received a break signal.
Serial line connecting BICU and
paper tray unit unstable
External noise
BICU board and LCT main board
connection defective or loose
Optional paper feed unit interface
board defective
BICU board defective
Communication timeout error
between BICU and LCT
626 C
The BICU does not receive a
response after 3 attempts within 100
ms to send data to the LCT.
Serial line connecting BICU and
LCT unit unstable
External noise
BICU board and LCT main board
connection defective or loose
LCT interface board defective
BICU board defective
Communication break error between
BICU and LCT
627 C
The BICU cannot communicate with
the LCT unit because it has received
a break signal.
Serial line connecting BICU and
LCT unit unstable
External noise
BICU board and LCT main board
connection defective or loose
LCT interface board defective
BICU board defective
BICU control data transfer sumcheck
error
640 D
A sampling of control data sent from
the BICU to the controller reveals a
sumcheck error. Only the logging
count is performed.
Controller board defective
External noise
BICU board defective
BICU control data transfer abnormal641 D
Data send from BICU to controller
failed after 3 attempts.
Controller board defective
External noise
BICU board defective
Engine response error670 C
After powering on the machine, a
response is not received from the
engine within the specified time.
BICU defective
Controller board defective
GAVD block I
2
C bus error690 A
An error is detected in the GAVD
communication I
2
C control register of
the GABIC2.
I2C bus on BICU defective