Duplex Unit
M065/M066 4-116 SM
4.12 DUPLEX UNIT
4.12.1 DUPLEX UNIT
1. Open the duplex unit.
2. Connector cover (
p.4-12 "Inner Right Front Cover")
3. Disconnect the six harnesses (
p.4-12 "Inner Right Front Cover").
4. Remove the ground screw [A].
5. Release the right arm [A] (
x 1).
Work carefully when releasing the right arm. This is because the right arm has
strong tension and this may cause injury.