Process Control Results
SM Appendix 4-5 M065/M066
Appendix:
Process
Control Error
Conditions
Vsg Adjustment Result
SP3-325-001 to -010 (Vsg Adjustment Result)
No. Result Description Possible Causes/Action
1 O.K
Vsg adjustment
is correctly done.
-
2
ID sensor
adjustment
error
Vsg cannot be
adjusted within
4.0 ±0.5V.
Dirty ID sensor (toner, dust, or foreign
material)
Dirty transfer belt
Scratched image transfer belt
Defective ID sensor
Poor connection
Defective IOB
1. Clean the ID sensor.
2. Check the belt cleaning. Clean or replace the
transfer belt.
3. Replace the image transfer belt.
4. Replace the ID sensor.
5. Check the connection.
6. Replace the IOB board.
3
ID sensor
output error
ID sensor output
is more than
"Voffset
Threshold"
(SP3-324-004)
Defective ID sensor
Poor connection
Defective IOB
1. Replace the ID sensor.
2. Check the connection.
3. Replace the IOB board.
9
Vsg
Adjustment
error
Vsg adjustment
has not been
completed.
Other cases
Retry SP3-321-010.