Process Control Results
SM Appendix 4-3 M065/M066
Appendix:
Process
Control Error
Conditions
4.1.2 PROCESS CONTROL SELF-CHECK RESULT
Displayed number shows results of each color sensor check.
00000000 = YYCCMMKK
SP3-012-001 to -010 (Process Control Self-check Result)
No. Result Description Possible Causes/Action
11
Successfully
completed
Process control
self-check
successfully
completed.
Check the Vsg adjustment. See the "Vsg
Adjustment Result" following this table.
41 Vt error
Vt maximum or
minimum error is
detected.
Defective development unit
Vt maximum error and an image is faint:
1. Replace the toner supply pump unit.
Vt maximum error and an image is O.K:
1. Replace the development unit.
2. Replace the IOB board.
Vt minimum error:
1. Replace the development unit.
2. Replace the IOB board.
53
ID sensor
coefficient
(K5) detection
error
Not enough data can
be sampled.
Solid image is not sufficient density:
1. Retry the process control.
2. Replace the ID sensors.
3. Replace the IOB board.
Solid image is O.K.
1. Replace the ID sensors.
2. Replace the IOB board.
ID sensor is dirty:
1. Clean the ID sensors.
2. Retry the process control.
54
ID sensor
coefficient
(K5)
maximum/
minimum error
When the K5 is more
than the value of
SP3-362-003 or less
than the value of
SP3-362-004, the
ID sensor pattern density is too high
or low.
ID sensor or shutter is defective.
Same as 53