SC Tables
SM Appendix 3-7 M065/M066
Appendix:
Service Call
Conditions
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
237 D
FGATE OFF error: C
The PFGATE ON signal still asserts within 5 seconds after
processing the image in normal job or MUSIC (line position
adjustment) for end position [C].
The PFGATE ON signal still asserts when the next job starts.
See SC 230 for troubleshooting details.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
240 C LD error: K or C
241 C LD error: Y or M
- -
The bridge board detects LDB error a few times consecutively when
LDB unit turns on after LDB initialization.
Worn-out LD
Disconnected or broken harness of the LD
1. Replace the harness of the LD.
2. Replace the laser unit.
3. Replace the bridge board.
⇒
⇒
Rev. 12/14/2011