SC Tables
SM Appendix 3-51 M065/M066
Appendix:
Service Call
Conditions
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
864
CTL
D
HDD: CRC error
While reading data from the HDD or storing data in the HDD, data
transmission fails.
Defective HDD
Replace the HDD.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
865
CTL
D
HDD: Access error
An error is detected while operating the HDD.
Defective HDD
Replace the HDD.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
866
CTL
B
SD card authentication error
A correct license is not found in the SD card.
SD-card data is corrupted.
Store correct data in the SD card.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
867
CTL
D
SD card error
The SD card is ejected from the slot.
1. Install the SD card.
2. Turn the main switch off and on.