System Service Mode
M065/M066 8-26 SM Appendix
102 Offset: 182: Color *ENG
[-15 to 15 / 0/ 1 step]
103 Offset: 85: Color *ENG
[-80 to 80 / 0/ 1 step]
130
OpcMot (Drum Motor) Adjust
Control
*ENG
[0 to 1 / 1/ 1 step]
1902 [Gain Control]
001 Execute *ENG Execute drum phase adjustment.
002 Result *ENG
[0 to 3 / 0/ 1]
Displays the result of drum phase
adjustment.
0: Successfully done
2: Sampling failure
3: Insufficient detection number
003 Auto Execute *ENG
[0 or 1 / 1/ -]
Turns the automatic drum phase
adjustment on or
off.
0: Off, 1: On
1907 [Feed Timing Adj.] DFU
001 Feed-Solenoid ON: Plain *ENG
[-10 to 40 / 0/ 2.5 mm/step]
002 Feed-STM OFF: Plain *ENG
[-10 to 10 / 0/ 1 mm/step]
003 Feed-STM ON: Plain *ENG
004 Feed-Solenoid ON: Thick *ENG
[-10 to 40 / 0/ 2.5 mm/step]
005 Feed-STM OFF: Thick *ENG
[-10 to 10 / 0/ 1 mm/step]
006 Feed-STM ON: Thick *ENG
007 Feed-Start: Low *ENG
014 By-pass Solenoid ON: Low *ENG
[-10 to 40 / 0/ 1 mm/step]
015 By-pass Solenoid ON: Middle *ENG