System Service Mode
SM Appendix 8-43 M065/M066
Appendix:
SP Mode
Tables
2145
[ID Sensor Check Result]
Displays the minimum result 2 values of the ID sensor check.
Front, Center, Rear: ID sensors for the automatic line position adjustment and
the process control
001 Minimum 2: Bk *ENG
[0 to 5.5 / 0 / 0.01V/step]
002 Minimum 2: C *ENG
003 Minimum 2: M *ENG
004 Minimum 2: Y *ENG
005 Minimum 2: Front *ENG
006 Minimum 2: Center *ENG
007 Minimum 2: Rear *ENG
2150
[Area Mag. Correction] LD Pulse Area Correction (Color, Area) FA
Adjusts the magnification for each area. The main scan (297 mm) is divided
into 13 areas. Area 1 is at the front side of the machine (left side of the image)
and area 13 is at the rear side of the machine (right side of the image).
Decreasing a value makes the image shift to the left side on the print.
Increasing a value makes the image shift to the right side on the print.
1 pulse = 1/16 dot
027 Bk: LD1 Area0 *ENG
[-255 to 255 / 0 / 1sub-dot/step]
028 Bk: LD1 Area1 *ENG
[-255 to 255 / -233 / 1sub-dot/step]
029 Bk: LD1 Area2 *ENG
[-255 to 255 / -193 / 1sub-dot/step]
030 Bk: LD1 Area3 *ENG
[-255 to 255 / 58 / 1sub-dot/step]
031 Bk: LD1 Area4 *ENG
032 Bk: LD1 Area5 *ENG
[-255 to 255 / 143 / 1sub-dot/step]
033 Bk: LD1 Area6 *ENG
034 Bk: LD1 Area7 *ENG
[-255 to 255 / 47 / 1sub-dot/step]