System Service Mode
SM Appendix 8-171 M065/M066
Appendix:
SP Mode
Tables
2930
[P-Transfer:Bias Limit] DFU
Paper Transfer Roller Feed-back: Threshold Adjustment
Adjusts the threshold between high resistance (division 1) and low resistance
(division 2) at the paper transfer roller.
001 Bias *ENG
[0 to 7000 / 6000 / 10 –V/step]
2941 [Dev. Bias Down Mode] DFU
001 T5: Bk: Standard *ENG
[-140 to 140 / 0 / 10 msec /step]
002 T7: FC: Standard *ENG
003 T5: Bk: Low *ENG
[-210 to 210 / 0 / 10 msec /step]
004 T7: FC: Low *ENG
005 T5: Bk: Middle *ENG
006 T7: FC: Middle *ENG
2960 [Process Interval] DFU
001 Additional Time *ENG
[0 to 10 / 1 / 1 sec/step]
2971 [BW Non-Image:Bias ON] DFU
001 T1 BW:Bias On:Standard *ENG
[-360 to 80 / 0 / 10 msec/step]
002 T1 BW:Bias On:Middle *ENG
[-780 to 210 / 0 / 10 msec/step]
003 T1 BW:Bias On:Low *ENG