System Service Mode
M065/M066 8-174 SM Appendix
3014 [TD Sen Initial Set Result] Developer Initialization Result: Display
001
Display: YMCK *ENG
[0 to 9999 / - / 1 /step ]
1: Success
2 to 9: Failure
Displays the developer initialization result. See the "Error Condition Tables" in
the Process Control Error section for details on the meaning of each code.
All colors are displayed. Values are displayed in the order Y M C Bk.
e.g., 1 (Y) 1 (M) 2 (C) 1 (Bk): Initialization of Cyan failed but the others
succeeded.
3015 [Forced Toner Supply] Forced Toner Supply ([Color])
001 Execution: ALL -
[0 or 1 / 0 / 1 /step]
Executes the manual toner supply to
the development unit.
002 Execution: COL (MCY) -
003 Execution: Bk -
004 Execution: C -
005 Execution: M -
006 Execution: Y -
3016
[Forced Toner Supply Cntl] Forced Toner Supply Setting ([Color])
Specifies the manual toner supply time for each color.
001 Supply Time: Bk *ENG
[0 to 30 / 4 / 1 sec/step]
002 Supply Time: C *ENG
003 Supply Time: M *ENG
004 Supply Time: Y *ENG