System Service Mode
M065/M066 8-222 SM Appendix
3641
[Charge DC Control: Display]
Standard: 260 mm/sec
Displays the charge AC voltage adjusted with the process control for each
color.
001 Standard Speed:Bk *ENG
[0 to 3 / 1.75 / 0.01 kV/step]
002 Standard Speed:C *ENG
003 Standard Speed:M *ENG
004 Standard Speed:Y *ENG
3651
[LD Power Control: Display]
Standard: 260 mm/sec, Middle: 182 mm/sec, Low: 85 mm/sec
Displays the LD power adjusted for each environment.
001 Standard Speed:Bk *ENG
[0 to 200 / 100 / 1 %/step]
002 Standard Speed:C *ENG
003 Standard Speed:M *ENG
004 Standard Speed:Y *ENG
005 Middle Speed:Bk *ENG
006 Middle Speed:C *ENG
007 Middle Speed:M *ENG
008 Middle Speed:Y *ENG
009 Low Speed:Bk *ENG
010 Low Speed:C *ENG
011 Low Speed:M *ENG
012 Low Speed:Y *ENG