System Service Mode
SM Appendix 8-281 M065/M066
Appendix:
SP Mode
Tables
016 Page: Fusing Unit
017 Page: Fusing Roller
018 Page: Fusing Belt
019 Page:PTR Unit
020 Page:ITB T-Collect Bottle
-031 to
-048
Displays the number of revolutions of motors or clutches for each current
maintenance unit.
[0 to 9999999 / 0 / 1 revolution/step ]
When a unit is replaced, the machine automatically detects that the new unit
is installed. Then, the current PM counter value is automatically moved to the
PM Counter - Previous (SP7-906-31 to 49) and is reset to "0". The total
number of revolutions made with the last unit replaced can be checked with
SP7-906-31 to 49.
031 Rotation: PCU: Bk
032 Rotation: PCU: C
033 Rotation: PCU: M
034 Rotation: PCU: Y
035 Rotation: Development Unit: Bk
036 Rotation: Development Unit: C
037 Rotation: Development Unit: M
038 Rotation: Development Unit: Y
043 Rotation:ITB Unit
044 Rotation: ITB Cleaning Unit
045 Rotation: Fusing Unit