Adjustment after Replacement
SM 4-72 D245/D246/D247
Magnification
Use an S5S test chart to do the following adjustment.
A: Sub scan magnification
1. Place the test chart on the exposure glass and make a copy from one of the feed
stations.
2. Check the magnification ratio and adjust using the following SP mode if necessary.
SP No. SP Name Adjustment Range
SP4-008-001 Sub scan Mag. Adj ±1.0 %