Engine SP Mode
SM 5-25 D245/D246/D247
System
Maintenance
2934 [ID Sens PWM Set]
2-934-001
Dilay *ENG [0 to 1023 / 200 / 1 / step]
Displays ID Sensor PWM value.
2-933-003
Upper Limit Corrc *ENG DFU
2935 [ID.Sens Initializ]
Executes ID Sensor initialization. It must be done after replacing the ID
sensor. This SP clears PWM value and executes Vsg adjustment again,
then resets PWM value.
2-935-001
- ENG [Execute]
2937 [ID.Sens Coef :Set]
Adjusts the coeficience for the Vsp/Vsdp adjustment.
2-937-001
Vsp Coef *ENG [0.50 to 1.50 / 1.00 / 0.01 / step]
2-937-002
Vsdp Coef *ENG [0.50 to 1.50 / 1.00 / 0.01 / step]
2-937-003
Sens Chara Coef *ENG [0.10 to 1.50 / 1.00 / 0.01 / step]
2992 [After T Sens Err]
2-992-001
Upper Threshold *ENG DFU
2-992-002
Lower Threshold *ENG DFU
2-992-003
Thresh Num UpCoun *ENG DFU
2-992-004
Thresh Num LoCoun *ENG DFU