SC Code Descriptions
SM 6-11 D245/D246/D247
Troubleshooting
SC No. Level Error Name/Error Condition/Major Cause/Solution
ID sensor defective
ID sensor harness damaged.
ID sensor not connected correctly.
MPU defective
Laser unit defective
Imaging density fault
HVPS board defective
ID sensor dirt
Clean the ID sensor.
Replace the ID sensor.
Replace and reset the ID sensor harness.
Replace the MPU.
Replace the HVPS board.
SC No. Level Error Name/Error Condition/Major Cause/Solution
354-00 B ID sensor: Auto adjustment timeout error (detailed)
If Vsg is not automatically adjusted to 4.0±0.2 V twice
consecutively when the ID sensor is adjusting Vsg automatically,
this SC is issued (only when the SP5-995-001 is set to “1”).
ID sensor defective
ID sensor harness damaged.
ID sensor not connected correctly.
MPU defective
Laser unit defective
Imaging density fault
HVPS board defective
ID sensor dirt
Clean the ID sensor.
Replace the ID sensor.
Replace and reset the ID sensor harness.
Replace the MPU.
Replace the HVPS board.