1.SC Codes
197
SC665-04
Error Name
IOB Does Not Start
Pattern
D
Error Condition
The IOB does not start.
Major Cause
1. Connector is not connected properly.
2. Connection between IOB and BiCU is not connected properly.
3. IOB is defective.
4. BiCU is defective.
Solution
1. Reconnect the connectors (BiCU, IOB).
2. Replace the harness between the BiCU and the IOB.
3. Replace the IOB.
4. Replace the BiCU.
Be careful not to bend the pins of the connector.