1.SC Codes
356
SC750-83
Error Name
Perfect Binder: Glue Level Thermistor Error 2
Pattern
D
Error Condition
After glue warm-up is completed, the glue level thermistor detected a temperature of less than 100
degrees for more than 10 sec.
Major Cause
ï‚· Glue level thermistor defective
ï‚· Glue heater defective
ï‚· Slave board defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the gluing unit.
ï‚· Replace the slave board.
SC750-84
Error Name
Perfect Binder: Thermistor Disconnect Error
Pattern
D
Error Condition
The glue abnormal temperature thermistor detected a temperature of less than 5 degrees for 1 sec., or
more than 10 sec. after power on.
However, if the thermistor detected less than 100 degrees after measuring temperature at start up,
temperature is checked again after 50 sec.
Major Cause
ï‚· Glue abnormal temperature thermistor defective
ï‚· Glue heater defective
ï‚· Slave board defective