1.SC Codes
623
Pattern
D
Error Condition
Unexpected operation from the software.
Major Cause
ï‚· Parameter error
ï‚· Internal parameter error
ï‚· Insufficient work memory
ï‚· Operation error caused by defects that are usually not detected by SC.
Solution
ï‚· Turn the main power OFF and ON.
ï‚· Reinstall the software of the controller and BiCU board.
SC991-00
Error Name
Recoverable Software Operation Error
Pattern
C
Error Condition
Software attempted an unexpected operation.
Different from SC990, this SC detects errors that can be recovered to allow continued operation.
Major Cause
ï‚· Parameter error
ï‚· Internal parameter error
ï‚· Insufficient work memory
ï‚· Operation error caused by defects that are usually not detected by SC.
Solution
Logging only
SC992-00
Error Name
Undefined SC Issued

Table of Contents