EasyManua.ls Logo

Ricoh Pro 8320 - Ground Plates that Require Checks; SC325, SC395 Grounding Faults

Ricoh Pro 8320
963 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5.Other Information
862
SC325, SC395 Grounding Faults
This section describes how to deal with two service codes:
ï‚· SC325: Development motor error
ï‚· SC395: Drum motor error
Cause
One or more deformed or dirty ground plates in the drum cleaning unit are causing grounding faults and
generating electrical noise that is interfering with the motor control signals that control operation of the
drive motor.
ï‚· SC325 occurs most frequently when electrical noise interferes with the drive motor control
signals.
Solution
1. Inspect the four ground plates on the drum cleaning unit.
2. Clean the plates if they are covered with toner or grease, and then replace any plate if it is
deformed.
Ground Plates that Require Checks
No.
Description
1
Ground Plate
2
Ground Plate Covers
3
PCU Slide Rail Stopper
4
Ground Plate Stays
*
1
: These are new service parts.
No. 1 Ground Plate

Table of Contents

Other manuals for Ricoh Pro 8320