EasyManuals Logo

Rigol DHO800 Series User Manual

Rigol DHO800 Series
253 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #222 background imageLoading...
Page #222 background image
Number of Points
A 4-byte integer, indicating the number of waveform points in
the data.
Count A 4-byte integer. It is fixed to 0.
X Display Range
A 4-byte float, indicating the X-axis duration of the waveform
that is displayed. For time-domain waveforms, it indicates the
duration of the display. If the value is zero, then no data has
been acquired.
X Display Origin
An 8-byte double-precision floating-point, indicating the X-
axis value at the left edge of the screen. For time-domain
waveforms, it indicates the time at the start of the display. The
value is treated as a double precision 64-bit float point
number. If the value is zero, then no data has been acquired.
X Increment
An 8-byte double-precision floating-point, indicating the
duration between data points on the X-axis. For time-domain
waveforms, it indicates the time between points. If the value is
zero, then no data has been acquired.
X Origin
An 8-byte double-precision floating-point, indicating the X-
axis value of the first data point in the data recording. For
time-domain waveforms, it indicates the time of the first
point. The value is treated as a double precision 64-bit float
point number. If the value is zero, then no data has been
acquired.
X Units
A 4-byte integer, indicating the unit of measurement for X
values in the acquired data. It is fixed to 2.
- 0 = Unknown
- 1 = Volts (V)
- 2 = Seconds (s)
- 3 = Constant
- 4 = Amps (A)
- 5 = Decibel (dB)
- 6 = Hertz (Hz)
Y Units
A 4-byte integer, indicating the unit of measurement for Y
values in the acquired data. The possible values are listed
above under X Units.
Date
A 16-byte character array, indicating the date when the file is
saved.
Time
A 16-byte character array, indicating the time when the file is
saved.
Store and Load
DHO800 User Guide
208
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.

Table of Contents

Other manuals for Rigol DHO800 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DHO800 Series and is the answer not in the manual?

Rigol DHO800 Series Specifications

General IconGeneral
Channels2 or 4 analog channels
Vertical Resolution12-bit
Vertical Sensitivity1 mV/div to 10 V/div
Timebase Range1 ns/div to 1000 s/div
Power Supply100-240 VAC, 50/60 Hz
Waveform Capture Rate1, 000, 000 wfm/s
InterfacesUSB Host, USB Device, LAN
Digital ChannelsOptional 16-channel MSO
Protocols DecodingI2C, SPI, UART, CAN, LIN
Input Impedance1 MΩ
Trigger TypesEdge, Pulse, Video, Slope, Pattern, Duration, Timeout, Runt, Window

Related product manuals