2 Command System RIGOL
MSO2000A/DS2000A Programming Guide
2-97
:FUNCtion:WRECord:OPERate
Syntax
:FUNCtion:WRECord:OPERate <oper>
:FUNCtion:WRECord:OPERate?
Description
Start or stop the waveform recording; or query the current status of the waveform recording.
Parameter
Name Type Range Default
<oper> Discrete {RECord|STOP} STOP
Return Format
The query returns REC or STOP.