68 SteelFusion Edge Hardware and Maintenance Guide
Replacing SteelFusion Edge Components Replacing fans
To replace the fans in the 1U SteelFusion Edge appliances
1. Remove the chassis cover.
See “Opening the bezel on page 44.
2. Unplug the fan cables from the cable jacks on the motherboard.
3. Pull the fan unit up and out of the chassis. The fans are encased in one unit.
4. Seat the fan unit on the metal peg on the floor of the chassis.
5. Plug the cables of the replacement fan unit into the cable jacks.
6. Replace the chassis cover.
Note: If the RiOS IPMI alarm triggers when you open the chassis cover, run the clear hardware error-log command
in the CLI to clear the alarm. For details, see the Riverbed Command-Line Interface Reference Manual.