3.7. NOISE LEVEL
The values relating to airborne noise have been detected in compliance with standards:
-
UNI EN ISO 3744
-
EN ISO 11201
Description
Average sound pressure
level (Lpm)
Emitted sound power level
(Lwa)
Level at operator position
(Lop)
Operation in working
conditions
56,2 dB (A)
72,0 dB (A)
56,5 dB (C)
Caution - warning
Prolonged exposure above 80 dB (A) can be harmful.
The use of appropriate protection systems is recommended (earmuffs, ear plugs, etc.).
3.8. INSTALLATION ENVIRONMENT CHARACTERISTICS
The place where the machine is to be installed must be carefully selected taking into account the environment conditions
in order to have correct and risk-free operating conditions.
Therefore we suggest to take into account the following prerequisites:
- An appropriate ambient temperature (see “Technical data”).
- A perimeter area that must be left around the immediate working area, also for safety reasons (see Perimeter
areas”).
- A flat surface, steady and without vibrations with adequate load bearing capacity, considering also the weight of
palletised loads.
- The area must feature suitable sockets for compressed air and power distribution.
Danger - warning
Using this machine in explosive environments or when exposed to atmospheric agents is strictly forbidden.