EasyManua.ls Logo

Rosemount 3051S - Page 148

Rosemount 3051S
190 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Specifications and Reference Data
September 2017
Reference Manual
00809-0100-4803, Rev GA
Specifications and Reference Data
140
G12 Vertical mount level flange 2-in. ANSI class 300 SST N/A N/A
G14
(8)
Vertical mount level flange 2-in. ANSI class 150 Cast C-276 N/A N/A
G15
(8)
Vertical mount level flange 2-in. ANSI class 300 Cast C-276 N/A N/A
G21 Vertical mount level flange 3-in. ANSI class 150 SST N/A N/A
G22 Vertical mount level flange 3-in. ANSI class 300 SST N/A N/A
G31 Vertical mount level flange DIN- DN 50 PN 40 SST N/A N/A
EB6 Assemble to primary element with manifold and coplanar flange, CS, Alloy C-276
F32
Bottom vent traditional
flange
1
/4–18 NPT SST 316 SST N/A
F42
Bottom vent traditional
flange
RC
1
/4 SST 316 SST N/A
F62
DIN-compliant traditional
flange
1
/4–18 NPT SST 316 SST M10 bolting
F72
DIN-compliant traditional
flange
1
/4–18 NPT SST 316 SST M12 bolting
G41 Vertical mount level flange DIN- DN 80 PN 40 SST N/A N/A
Transmitter output
A 4–20 mA with digital signal based on HART Protocol
Housing style Material Conduit entry size
1A Plantweb housing Aluminum
1
/2–14 NPT
1B Plantweb housing Aluminum M20 1.5
1J Plantweb housing SST
1
/2–14 NPT
1K Plantweb housing SST M20 1.5
1C Plantweb housing Aluminum G
1
/2
1L Plantweb housing SST G
1
/2
Options (include with selected model number)
RTD cable (RTD sensor must be ordered separately)
C12 RTD input with 12 ft. (3,66 m) of shielded cable
C13 RTD input with 24 ft. (7,32 m) of shielded cable
C14 RTD input with 75 ft. (22,86 m) of shielded cable
C20
(12)
RTD input with 27-in. (69 cm) of armored shielded cable
C21 RTD input with 4 ft. (1,22 m) of armored shielded cable
C22 RTD input with 12 ft. (3,66 m) of armored shielded cable
C23 RTD input with 24 ft. (7,32 m) of armored shielded cable
C24 RTD input with 75 ft. (22,86 m) of armored shielded cable
C30
(12)
RTD input with 25-in. (64 cm) of ATEX/IECEx Flameproof cable
C32 RTD input with 12 ft. (3,66 m) of ATEX/IECEx Flameproof cable
C33 RTD input with 24 ft. (7,32 m) of ATEX/IECEx Flameproof cable
C34 RTD input with 75 ft. (22,86 m) of ATEX/IECEx Flameproof cable
C40
(12)
RTD input with 34-in. (86,36 cm) shielded cable and 24-in. (60,96 cm) FM Approved coupling flex
C41
(12)
RTD input with 40-in. (101,60 cm) shielded cable and 30-in. (76,20 cm) FM Approved coupling flex
Table A-6. Rosemount 3051S Scalable MultiVariable Transmitter Ordering Information
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to
additional delivery lead time.

Table of Contents