EasyManua.ls Logo

Rosemount 3051S - Page 59

Rosemount 3051S
190 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
51
Reference Manual
00809-0100-4803, Rev GA
Configuration
September 2017
Configuration
If conversion factor tables or internet search engines are used to determine the Base per Custom value, it
is important to enter the Custom Unit in the “From” field and the Base Unit in the “To” Field.
To calculate the Base per Custom value for a custom unit not shown in Table 2-9 on page 39, see the
example:
Totalizer conversion example
To find the Base per Custom relationship for a custom unit of millions of standard cubic feet (mmscf) and
a base unit of standard cubic feet (StdCuft), input the following:
Custom Unit = mmscf
Base Unit = StdCuft
Because:
1 mmscf (Millions of Standard Cubic Feet) = 1000000 StdCuft (Standard Cubic Feet)
Therefore:
Base per Custom = = = 1000000
Figure 2-35. Totalizer Custom Units - Totalizer Example
Number of Base Units
1xCustomxUnit
----------------------------------------------------------------------
1000000 StdCuft
1mmscf
-------------------------------------------------

Table of Contents

Related product manuals