Rosemount 8712
E-16
Model 10D1419 Sensor
to Rosemount 8712
Transmitter
Connect coil drive and electrode cables as shown in Figure E-14.
Figure E-14. Wiring Diagram for
Fischer and Porter Sensor
Model 10D1419 and Rosemount
8712
Table E-12. Fischer and Porter Model 10D1419 Sensor Wiring Connections
Rosemount 8712
Fischer and Porter
Model 10D1419 Sensors
1L1
2 L2
3
17 3
18 1
19 2
ROSEMOUNT
8712
TRANSMITTER
3
2
1
18
L1
L2
16
17
Electrode Connections
Coil Connections
This is a pulsed DC magnetic flowmeter.
Do not connect AC power to the sensor
or to terminals 1 and 2 of the
transmitter, or replacement of the
electronics board will be necessary.