Reference Manual
00809-0100-4664, Rev BA
January 2010
E-19
Rosemount 8712
Model 10D1435 Sensor
(Integral) to
Rosemount 8712
Transmitter
Connect coil drive and electrode cables as shown in Figure E-17.
Figure E-17. Wiring Diagram for
Fischer and Porter Sensor
Model 10D1430 (Integral) and
Rosemount 8712
Table E-15. Fischer and Porter Model 10D1435 Sensor (Integral)
Wiring Connections
Rosemount 8712
Fischer and Porter
Model 10D1435 Sensors (Integral)
1M1
2 M2
G
17 3
18 1
19 2
Interconnection
Department
ROSEMOUNT 8712
TRANSMITTER
16
18
17
M2
M1
L2/N
L1/L
G
1
2
3
16
17
18
L2/N
L1/L
U1
G
Coil
Connections
Disconnect and
feed through
Magnetic Driver
Assembly
3
U2
G
Electrode
Connections
This is a pulsed DC magnetic flowmeter.
Do not connect AC power to the sensor
or to terminals 1 and 2 of the
transmitter, or replacement of the
electronics board will be necessary.