Reference Manual
00809-0100-4664, Rev BA
January 2010
E-27
Rosemount 8712
Foxboro Generic Sensor
to 8712 Transmitter
Connect coil drive and electrode cables as shown in Figure E-25.
Figure E-25. Generic Wiring
Diagram for Foxboro Sensors
and Rosemount 8712
Table E-23. Foxboro Generic Sensor Wiring Connections
Rosemount 8712
Foxboro
Generic Sensors
1L1
2 L2
Chassis Ground
17 Any Shield
18 Black
19 White
Electrodes
Coils
Shield/Ground
ROSEMOUNT 8712
TRANSMITTER
FOXBORO
SENSOR
L2
L1
White
Black
Any Shield
Fuse
This is a pulsed DC magnetic flowmeter.
Do not connect AC power to the sensor
or to terminals 1 and 2 of the
transmitter, or replacement of the
electronics board will be necessary.