Reference Manual
00809-0100-4004, Rev BA
August 2010
4-13
Rosemount 8800D
Number of Required Preams
This is the number of preambles required by the 8800D for HART
communications.
Number of Response Preams
This is the number of preambles sent by the transmitter in response to any
host request.
Burst Mode
Burst Mode Configuration
The Rosemount 8800D includes a burst mode function that broadcasts the
primary variable or all dynamic variables approximately three to four times a
second. The burst mode is a specialized function used in very specific
applications. The burst mode function enables you to select the variables to
broadcast while in the burst mode and to select the burst mode option.
The Burst Mode variable enables you to set the Burst Mode to the needs of
your application. Options for the Burst Mode setting include:
Off–Turns off the Burst Mode so that no data are broadcast on the loop.
On–Turns Burst Mode on so that the data selected under Burst Option are
broadcast over the loop.
Additional command options may appear that are reserved and do not apply
to the Rosemount 8800D.
Field Comm. 1, 4, 2, 3, 2
Field Comm. 1, 4, 2, 3, 3
Field Comm. 1, 4, 2, 3, 4

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rosemount 8800D Series and is the answer not in the manual?

Rosemount 8800D Series Specifications

General IconGeneral
TypeVortex Flow Meter
Measurement PrincipleVortex Shedding
Operating Temperature-40 to 185°F (-40 to 85°C)
Storage Temperature-40 to 185°F (-40 to 85°C)
Communication ProtocolsFOUNDATION Fieldbus
Material316 stainless steel
Fluid TypeLiquid, Gas, Steam
Line Size1/2 to 8 inches (15 to 200 mm)
ApprovalsATEX, IECEx, CSA, FM
Output Signal4-20 mA
Process ConnectionFlanged, Wafer, Threaded
Electrical ConnectionM20
Protection RatingIP66
Mounting StyleWafer, Flanged