Programming Instructions
Page 41 AC-115 Hardware Installation and User's Guide
Mode
Door
Oran
e
hear a long beep and the controller will exit Programming
Mode and return to Normal Mode.
• The Mode LED will turn green
4.26 Setting up the Duress Event Actions
1. Enter Programming Mode
• Mode LED will turn orange
2. Press ”44” to enter Menu 44
• The Mode LED will turn red
3. Enter the 2-digit Duress Event settings.
• N1 - determines if the auxiliary relay is activated when a
Duress Event occurs.
Enter “1” to enable this feature
Enter “0” to disable this feature
• N2 - determines if the internal siren is activated when a
Duress Event occurs.
Enter “1” to enable this feature
Enter “0” to disable this feature
4. If the 2-digit Duress Ajar Event settings are entered
correctly, the Duress Event settings will be updated and the
controller will return to Programming Mode.
• The Mode LED will turn orange
If the 2-digit Duress Event settings are entered incorrectly,
the Duress Event settings will NOT be updated. You will hear
a long beep and the controller will exit Programming Mode
and return to Normal Mode.
• The Mode LED will turn green
4.27 Setting up the Release to Exit (REX) Event
Actions
1. Enter Programming Mode
• Mode LED will turn orange
Mode
Door
Green
Mode Door
Oran
e
4 4
Mode
Door
Red
N1 N2
Mode
Door
Green
Mode
Door
Oran
e