EasyManua.ls Logo

Rotax 915 i A SERIES - Flushing the Cooling System

Rotax 915 i A SERIES
160 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BRP-Rotax
MAINTENANCE MANUAL
FLUSHING THE COOLING SYSTEM
General note
m WARNING
Risk of Burns!
Never open the radiator cap when the cooling system is hot. For safety’s sake, cover
cap with a rag and open slowly. Sudden opening of the cap could provoke the escape
of boiling coolant and result in scalding.
Instruction To flush the coolant the following steps are necessary:
Step
Procedure
1
The system is flushed using pure water at a pressure of 2 bar (29 psi).
NNOOTTEE
For the flushing, open the lowest located coolant hose (either at
water pump or radiator).
2 Refill newly mixed coolant into the expansion tank (highest point of the cool-
ing system).
See Chapter 12-10-00 section Coolant check/replenish.
ATTENTION
Where water-free coolant is used, the cooling system must be drained of water
correspondingly after flushing. The residual water must not exceed the max. per-
missible limit prescribed by the coolant manufacturer.
Step
Procedure
3 Fit radiator cap.
4
NNOOTTEE
Run the engine for a minute and replenish coolant as required.
12–20–00
Page 20
December 01 2017
Effectivity: 915 i A Series
Edition 0/Rev. 0

Table of Contents