EasyManuals Logo

Rotax 915 i A SERIES Maintenance Manual

Rotax 915 i A SERIES
160 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #91 background imageLoading...
Page #91 background image
BRP-Rotax
MAINTENANCE MANUAL
Non compliance with fuel quality
Step
Procedure
2
Empty the fuel system according to the instructions of aircraft manufacturer.
3 Flush fuel system.
4
Check differential pressure.
5 Engine test run.
SMOOTH PERFORMANCE OF THE ENGINE
General note
m WARNING
Risk of electric shock!
Ignition “OFF” and system grounded! Disconnect negative terminal of battery.
Inspection Inspection of smooth performance of the engine should be performed at a temperature
about 0 °C to 60 °C (140 °F).
Engine runs sluggishly
Step
Procedure
1
Remove spark plug connector and remove 1 spark plug from each cylinder.
2 Torque must be determined with a suitable jig.
To do this, determine the maximum occurring torque on the propeller shaft
necessary to move the whole crank drive.
The torque must be max. 150 Nm (111 ft.lb).
If the maximum torque is exceeded, perform the following inspections:
Carry out detailed inspection of the affected gearbox components
Carry out detailed inspection of crank drive
Effectivity: 915 i A Series
Edition 0/Rev. 0
05–50–00
Page 29
December 01 2017

Table of Contents

Other manuals for Rotax 915 i A SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotax 915 i A SERIES and is the answer not in the manual?

Rotax 915 i A SERIES Specifications

General IconGeneral
BrandRotax
Model915 i A SERIES
CategoryEngine
LanguageEnglish

Related product manuals