BRP-Rotax
MAINTENANCE MANUAL
EXPANSION TANK, RADIATOR CAP
Figure 7.9: Expansion tank, radiator cap
1 Pressure relief valve 2 Return valve
3 Rubber seal 4
Pressure spring
5 Connection to overflow bottle 6
Opening pressure of the radiator cap
7
Sealing surface
8 Tube connections
9
Sight glass
General note To equalize pressure in the cooling system, an expansion tank is required. If the pressure
in the system rises above 1.2 bar (17.4 psi) as the coolant warms up, the pressure relief
valve (1) opens and the coolant can flow into the expansion tank via the line (5). When the
coolant cools down, the return valve (2) opens and the coolant is sucked back.
Radiator cap Inspect the rubber seal (3), the pressure spring (4) and the two valves incorporated in the
radiator cap for damage and leaks. If necessary, replace with a new original radiator cap
with 1.2 bar (17.4 psi) (6) opening pressure.
NNOOTTEE
The radiator cap must be tightened fully on the expansion tank.
Expansion tank Inspect sealing surface (7) and tube connection (8) of the expansion tank. Carry out visual
inspection of tank for damage and scuffing marks.
Effectivity: 915 i A Series
Edition 0/Rev. 0
12–20–00
Page 21
December 01 2017

Table of Contents

Other manuals for Rotax 915 i A SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotax 915 i A SERIES and is the answer not in the manual?

Rotax 915 i A SERIES Specifications

General IconGeneral
BrandRotax
Model915 i A SERIES
CategoryEngine
LanguageEnglish

Related product manuals