SCHEDULED MAINTENANCE CHECKS
Definition This section lists the periodic inspections which must be carried out after a specified peri-
ods of operation.
Intervals Periodic inspections are those which must be performed at 25, 100, 200, 600 hr. intervals
in accordance with Chapter 05-20-00 section Maintenance Schedule.
This means for example that. every 100 hr of operation a 100 hr. check must be carried
out. Every 200 hr. of operation a 100 hr. and the additional checks for 200 hr. must be car-
ried out.
Intervals –hours
25 hr 100
hr
200
hr
300
hr
400
hr
500
hr
600
hr
700
hr
to
2000
hr
100
hr
X X X X X X X X X
200
hr
X X X
600
hr
X
100 hr. check or
annual check
In order to demonstrate continued airworthiness, an engine must be inspected after
every 100 hours of operation or 12 months.
For the intervals between maintenance work, a tolerance of ±10 hr. is permissible, but
these tolerances must not be exceeded. This means that if a 100 hr. check is actually
carried out at 110 hr., the next check will be due at 200 hr. ±10 hr. and not at 210 hr. ±10
hr.
If maintenance is performed before the prescribed interval, the next maintenance check
is to be done at the same interval (e.g. if first 100 hr. check is done after 87 hours of op-
eration, the next 100 hr. check must be carried out after 187 hours of operation).
If engine has less than 100 hours of operation during one year a 100 hr. check must be
carried out. For the annual inspection a tolerance of ±2 months is given.
Special hr. check
NNOOTTEE
This maintenance schedule contains a column for a 50 hr. check. This check is
recommended by the manufacturer but not essential, with the exception of oil
change when operating with leaded AVGAS.
25-hr. check In order to demonstrate continued airworthiness, an engine must be inspected after the
first 25 hours of operation.
The checks performed at the 25 hr. inspection are the same as for the 100 hr. inspec-
tion. This applies both to newly delivered engines and to overhauled engines.
05–20–00
Page 2
December 01 2017
Effectivity: 915 i A Series
Edition 0/Rev. 0

Table of Contents

Other manuals for Rotax 915 i A SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotax 915 i A SERIES and is the answer not in the manual?

Rotax 915 i A SERIES Specifications

General IconGeneral
BrandRotax
Model915 i A SERIES
CategoryEngine
LanguageEnglish

Related product manuals