Step
Procedure
6
Install new oil filter.
7
Pour in approx. 3 l (0.8 gal (US)) of fresh oil.
8 After carrying out the oil change, the engine should be cranked by hand in
the direction of engine rotation (approx. 20 turns) to completely refill the en-
tire oil circuit.
OIL FILTER REMOVING
General note
m WARNING
Risk of burns and scalds. Hot engine parts.
Always allow engine to cool down to ambient temperature before starting work.
ATTENTION
To ensure correct functioning of the oil circuit and the forced flow lubrication,
use ORIGINAL-ROTAX®- oil filter only. Only these filters will ensure correct pres-
sure in the by-pass valve.
At every oil change, unscrew the oil filter and cut open using special tool taking care not to
produce chips.
Special tools To carry out the procedure the following tools are necessary: