BRP-Rotax
MAINTENANCE MANUAL
Step
Procedure
3
Engine test run. See chap. 12-20-00 section: Test run of engine.
4
Inspect the oil filter once more.
Contaminated
ATTENTION
If the oil circuit is contaminated, replace the oil cooler and flush the oil circuit.
See chapter 12–20–00 section: Flushing the oil circuit. Proper judgement re-
quires years of experience in repair of piston engines.
Figure 7.14: Oil filter
1
Filter housing
2 Filter cover
3
Gasket ring
4 Anti-drain membrane
5 Filter matt 6
Spring
Effectivity: 915 i A Series
Edition 0/Rev. 0
12–20–00
Page 31
December 01 2017