0.5 bar
(50 kPa)
Operating limit
(See Operators Manual 915 i Series)
Proceed as instructed
in table 6
Proceed as instructed
in table 5
0
1 min. Time
Figure 5.15: Overview and instruction
Oil pressure below minimum oil pressure on the ground
If noticed on ground, immediately stop the engine and determine the cause.
Inspect the complete lubrication system, trace cause and rectify.
If the oil pressure falls below the minimum value up to max. 0.5 bar (7.25 psi) and for max.
1 min., the cause must be determined.
Table 5: Oil pressure below minimum permissible oil pressure up to max. 0.5 bar
(7.25 psi) max. 1 min. in flight
Step
Procedure
1 Inspect all oil lines for restrictions and clear passage.
2
Verify oil quantity.
3 Inspect pressure sensor.
4
Inspect indicating instrument to specifications of the manufacturer, replace
as required.
5
Inspect crankcase pressure (See Installation Manual, latest issue.).
6 If no cause for the low oil pressure is found after the above checks, carry
out an oil change.
05–50–00
Page 24
December 01 2017
Effectivity: 915 i A Series
Edition 0/Rev. 0

Table of Contents

Other manuals for Rotax 915 i A SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotax 915 i A SERIES and is the answer not in the manual?

Rotax 915 i A SERIES Specifications

General IconGeneral
BrandRotax
Model915 i A SERIES
CategoryEngine
LanguageEnglish

Related product manuals