168 • Program Mode Programming Sam4s SPS-300 OP Manual v1.35
System Option Programming
At the PGM control lock position menu, press 3 for SYSTEM OPTION
Programming. The SYSTEM OPTION pg. 1 screen displays.
Refer to “System Options – Reference Information" on page 173 to make program
entries or changes, press the CASH key to finalize.
SYSTEM OPTION P1
BEEPER ACTIVE Y
RESERVED
CLERK ENTRY 0
0:PUSH 1:CODE
CLERK ASSIGNED WHEN CLERK KEY IS
PUSHED (1-00) 1
SYSTEM OPTION P2
CLERK IS Y:POP-UP N
N:STAY-DOWN
DRAWER NEEDS TO BE SHUT TO
OPERATE Y
ACTIVATE OPEN DRAWER ALARM N
Press
PAGE DOWN
to view the 2
nd
System Option
screen.
Press ENTER
after making a
change, or press
ENTER to
advance the
arrow to the next
option without
making a
change.
Press PAGE UP
to return to the
previous screen.
NOTE:
Be sure to press
ENTER after
changing a
selection. If you
do not press
ENTER, the
change will not
be accepted.
Press YES/NO
to toggle from
'Y' to 'N' for yes
or no decisions.
SYSTEM OPTION P3
SECONDS TO ALLOW DRAWER OPEN 30
(0-99)
ALLOW POST TENDER N
OPEN DRAWER ON POST TENDER
Y
ALLOW MULTIPLE RECEIPT
N
SYSTEM OPTION P4
CASH DECLARATION REQ
BEFORE REPORTS N
MGR CONTROL TO TEND.
NEGATIVE BALANCE N
ZERO BALANCE N
RESET TRANSACTION NO.ON Z RPT N
Press
PAGE DOWN
to view the 4
th
System Option
screen.
Press
PAGE DOWN
to view the 3
rd
System Option
screen.
The 1st System
Option screen.

Table of Contents