94 • Operations Sam4s SPS-300 OP Manual v1.35
Enter “0” and press the PLU key. The cursor will advance to the price field and
additional fields will display to allow entry of a unique descriptor and PLU tax status.
(Note: Group #1 Entry field added at software version 1.078.)
NOT FOUND PLU PROGRAM ?
SELECT COPY PLU
0
PRICE: 0
DESC :
TAX : 1N 2N 3N 4N
GROUP #1(1-20) 1
Enter the PLU price and press CASH. The cursor will advance to the descriptor
field.
Enter a descriptor using the descriptor method set up on your register (keyboard
overlay or descriptor code. See “Descriptor Programming Methods” on page 145.)
After the descriptor entry, press CASH. The cursor will advance to the TAX (1)
field.
Press the YES/NO key to toggle the tax status from N(o) to Y(es). Set the status for
the four possible tax rates and press CASH.
Beginning at software version 1.078 you can enter the Group #1 group assignment.
Press CASH; the PLU entry is completed.
Not Found PLU Report
Managers will typically use the “Not Found PLU Report” as a tool to update the PLU file. A list
of up to 50 not found PLU items can be retained in the report. When capacity is reached, you
must clear (Z) the Not Found PLU report.
To run an X Report of not found PLU’s, choose NOT FOUND PLU (selection #8) from
the Manager Mode menu
To run an Z Report of not found PLU’s, choose RESET NOT FOUND PLU (selection
#7) from the Z Mode menu.